Measure moving and rotating surface temperatures with Anritsu U and UX Series contact probes. Select the head, guard or wheel arrangement to suit the surface profile, temperature and operating conditions.
U series: Moving-surface probes with multiple head and mounting configurations.
UX series: Contact-support head that helps maintain contact during measurement.
Thermocouple: Type K or Type E.
Temperature: -50°C to 200°C or 250°C, depending on construction.
Anritsu MW series probes are ideal for measuring the temperatures at the surface of moving wires. Specific components may be combined to customize products for the needs of a customer's specific application.
Measure temperature inside semi-solid materials with Anritsu BT Series needle temperature probes. Choose the needle diameter, length and tip shape to suit the measurement depth and material being tested.
Thermocouple: Type K or Type E.
Temperature range: -200°C to 210°C, 300°C or 500°C, depending on model.
Needle options: Fixed or replaceable construction, with cut or sharp tips.
Spare parts: BTN replacement needles for compatible BT-3 to BT-8 models.
Measure the internal temperature of liquids and semi-solid materials with Anritsu BS Series temperature probes. Choose a fine sleeve-type probe or a grip-type assembly according to the measurement depth, access and handling requirements.
Thermocouple: Type K or Type E.
Probe diameter: 0.9–5.0 mm, depending on model and coating.
Temperature range: -200°C to 200°C, 300°C or 500°C, depending on construction.
Configuration: Select probe length, fluororesin coating, cable and connector.
The Anritsu AR-6500 series combines non-contact infrared measurement with a Type K contact thermometer input. Use a compatible contact probe as a reference for automatic emissivity setting.
Temperature options: -50 to 500°C or 0 to 1200°C, depending on model.
Small measurement area: Defined optics for checking individual surface targets.
Output options: AR-6501 versions provide a 1 mV/°C analog output.
Contact probes: Selected separately to suit the application.
The Anritsu FL Series fiber optic thermometers measure temperature in microwave, high-frequency and high-voltage environments where conventional electrical sensors can be difficult to use.
Model options: FL-2000 with one channel or FL-2400 with four channels.
Probe selection: Dedicated fiber optic probes for different temperatures, materials and operating conditions.
Integration: Analog temperature output and RS-232C communication.
Configuration: Temperature probes are selected separately and are not included with the instrument.
The Anritsu ACS II series provides controlled temperature sources for calibrating and checking contact temperature probes. Choose a dedicated surface calibrator, an internal probe calibrator or a combined system to suit your measurement work.
Surface calibration: ACS II-1000 to 300°C and ACS II-2000 to 500°C.
Internal probe calibration: ACS II-3000 to 500°C.
Combined capability: ACS II-4000 for surface and internal probes to 500°C.
The Isuzu TH27R (TH-27R) thermohygrograph is discontinued. For a replacement temperature and humidity chart recorder, choose the Sato NSII-Q (Sigma II).
Replacement options: Sato 7210-00 or 7211-00, depending on the temperature range required.
Paper recording: Records temperature and relative humidity on a rotating chart.
Before ordering: Confirm the recording period and matching chart paper.
The Sato SK-170GT WBGT heat stress monitor measures air temperature, humidity and globe temperature to calculate the Wet Bulb Globe Temperature index. Its portable design supports heat condition checks at workplaces, construction sites and sports facilities.
Black globe sensor: accounts for radiant heat in the measurement.
Indoor and outdoor modes: selectable WBGT calculation settings.
The Sato SK-1260 digital thermometer combines portable temperature measurement with stored readings and high/low alarms. Dedicated Type K thermocouple and thermistor probes support different measurement tasks.
Splash-resistant: IPX4 protection for everyday handling around wet work areas.
Memory: Store up to 180 readings manually or 120 readings automatically.
Temperature alarms: Set upper and lower limits for audible notification.
Standard probe set: Supplied with the SK-S100K Type K probe; other probes are optional.
The Sato SK-270WP-K waterproof digital thermometer replaces the SK-250WP for routine temperature checks in food preparation, production and laboratory work.
Standard probe included: S270WP-01, measuring from -40 to 250°C.
IP67 protection: Dustproof and waterproof body when the probe is correctly connected.
Simple operation: Display hold and automatic power-off.
Probe selection: Dedicated S270WP probes for different measurement tasks.
Monitor four measurement points with the Sato SK-L400T 4-channel temperature data logger. Connect Type K thermocouple probes, view all four readings together and record temperature data to an SD card.
Four-channel display: Compare temperatures on one backlit LCD.
Flexible recording: Select logging intervals from 1 second to 90 minutes.
Channel alarms: Set individual upper and lower temperature limits.
Probe selection: Thermocouple probes are purchased separately.