Ryutai Kogyo flowmeters provide local flow indication and, on selected models, signals for monitoring and control. Compare acrylic water meters, compact panel flowmeters, glass-tube instruments and EM metal-tube models. Replacement guidance is also available for existing MCF installations.
Choosing a flowmeter starts with what flows through the pipe and how you need to use the reading. A water line may need a straightforward visual indication, while a process installation may require a metal-tube instrument with an electrical output.
Explore the Ryutai Kogyo flowmeter range below to find a suitable starting point. Selection depends on the liquid or gas, flow range, operating conditions, connection requirements and available installation space.
Identification and replacement guidance for existing MCF installations, including discontinued MCF-V, MCF-II and MCF-H models.
Replacing an installed instrument while checking its flow range, dimensions, connections and electrical requirements.
Water flowmeters for local inspection
The ADF series uses an acrylic tapered tube so operators can read the flow directly at the instrument. It indicates instantaneous flow rather than accumulated water consumption.
For selection, provide the required water flow range, operating pressure and temperature, connection size and installation arrangement. If the liquid contains additives, identify them so material compatibility can be checked.
Panel and small-flow measurement
The GPB, GPC, PGH, GDR and AMF families offer different arrangements for compact flow measurement. GPB and GPC are glass-tube options, PGH covers purge-flow applications, GDR provides a compact threaded arrangement, and AMF uses an acrylic measuring tube.
Specify the medium and measuring range first, then confirm the mounting position, connection arrangement and whether a regulating valve is needed. For gas measurement, include the operating pressure and temperature so the scale can be selected correctly.
Glass, acrylic or metal tube?
GTF and GTV use glass measuring tubes; ATF and ATV use acrylic measuring tubes. These families allow direct observation of the float. Choose the construction according to the fluid, operating conditions and installation requirements.
The EM series provides a metal-tube alternative with magnetic transmission of the flow indication. Depending on the ordered configuration, options can include analogue output, totalising, pulse output or alarms. Confirm the required functions when requesting a quotation.
Replacing an older MCF flowmeter
MCF-V, MCF-II and MCF-H models are discontinued. The EM range is the replacement family to review, but an EM instrument should not be assumed to be a direct fit for every existing installation.
Send the complete MCF model code and a clear nameplate photograph, together with the connection dimensions, measured fluid, flow range and existing output details. This allows the proposed replacement to be checked against both the pipework and the receiving equipment.
Read and adjust flow at your equipment with Ryutai Kogyo panel flowmeters and purge meters. The GPB, GPC, PGH, GDR and AMF families offer glass or acrylic measuring tubes for direct local indication, with mounting and valve arrangements selected for the installation.
GPB and GPC: Glass tube panel and laboratory flowmeters.
PGH: Glass tube purge meter; successor to the older PGF series.
GDR: Compact glass tube flowmeter with threaded connections.
AMF: Acrylic tube panel flowmeter.
Select the model using the fluid, flow range, operating pressure, temperature and available panel space.
The Ryutai Kogyo GTF, ATF, GTV and ATV variable area flowmeters provide direct visual indication of liquid or gas flow. Choose the measuring tube and wetted materials to suit your fluid, pipework and operating conditions.
GTF: Glass tapered measuring tube.
ATF: Acrylic tapered measuring tube.
GTV: Glass tapered tube with PVC construction.
ATV: Acrylic tapered tube with PVC construction.
Standard installation is vertical with bottom-to-top flow. Measuring scales, connections and alarm options depend on the selected configuration.
The Ryutai Kogyo ADF water flowmeter provides a direct visual reading of instantaneous water flow through a transparent acrylic tapered tube. Its compact inline design suits local checks on water supply and circulation pipework.
Measurement: Variable area flow indication for water.
Connections: Rc 1/2, Rc 3/4 and Rc 1 threaded options.
Installation: Vertical mounting with flow from bottom to top.
Selection: Match the scale, connection size and wetted materials to your operating conditions.
The Ryutai Kogyo MCF metal tube flow transmitter provides flow indication and, depending on configuration, an electrical signal for remote monitoring equipment.
Legacy models: MCF-V, MCF-II and MCF-H are discontinued; the manufacturer identifies the EM series as the replacement range.
Replacement selection: Match the fluid, measuring range, installation dimensions and required output.
Existing installations: Provide the complete MCF or E-MCF code and a photograph of the instrument nameplate.
The Ryutai Kogyo EM series metal tube variable area flowmeter measures flow with a magnetically coupled indicator. Select local indication or additional electrical functions to suit your installation.
Fluid options: Models for clean liquids, gases and steam.
Body sizes: 15A to 150A, depending on model.
Functions: Local flow display, analogue output, totalising, pulse output and alarms, depending on configuration.
Replacement enquiries: EM-series selection is available for older MCF installations, subject to compatibility checks.