Explore Anritsu temperature measurement instruments, from handheld and printing thermometers to multi-channel data loggers and calibrators. Select compatible probes for stationary surfaces, moving targets, liquids and semi-solid materials.
Anritsu thermometers and temperature probes
Anritsu temperature instruments support spot checks, inspection records and measurements across multiple points. The range includes handheld thermometers, printing thermometers, data loggers, dedicated probes and calibration equipment.
Select the instrument and probe together. The thermometer provides the display and recording functions, while the probe must suit the target, contact arrangement and operating temperature.
Handheld and printing thermometers
Choose according to how readings will be used: a local display for routine checks, stored measurements for later review or a printed record at the measurement point.
Anritsu HR series handheld thermometers — compare basic, standard, LED-display and memory models. Match the fixed Type K or Type E input and ASP or ANP connector to your probe.
The target's shape and movement determine how the sensing head should make contact. For internal measurements, consider the material, insertion depth and probe dimensions.
BS series needle probes — insertion measurement in suitable liquids and semi-solid materials.
Browse the full temperature probe range for additional contact shapes and specialist measurement arrangements.
Multi-channel temperature data loggers
For measurements across several points, select the channel count, input types and recording interval before choosing the probes and software.
Anritsu AM-9000 series data loggers — six- and twelve-channel configurations with internal recording and USB communication. AMS-950 analysis software is sold separately.
Fiber optic temperature measurement
Some measurement environments require a dedicated sensing method. For microwave, high-frequency or high-voltage applications, describe the equipment and sensor position before selecting the measurement system.
Match the calibration source to the probe geometry and required test temperatures. Surface probes and insertion probes need different contact arrangements.
Measurement task: Describe the surface, liquid or material and how the sensor will reach it.
Temperature: Include normal operating values and expected peaks.
Probe compatibility: Confirm the sensor type, connector and complete probe code.
Required functions: Local display, memory, printing, multiple channels or external outputs.
A thermometer's display range does not establish the temperature limit of every connected probe. Check the sensing tip, cable and handle limits against the actual conditions.
Request an Anritsu quotation
Send your instrument and probe references, quantity and required delivery date. If you need help selecting a probe, include a photograph of the measurement target and its dimensions.
The Anritsu AP-400 and AP-450 printing thermometers produce temperature records directly at the measurement point. Use manual printing for inspection rounds or interval printing to follow temperature changes.
Built-in printer: Print readings with time information.
Memory: Store up to 100 readings for batch printing.
Model choice: AP-400 with ASP connector or AP-450 with ANP connector.
Probe selection: Match the fixed thermocouple type and connector; probes are sold separately.
The Anritsu AM-8000 series temperature datalogger is a portable instrument available in 6- and 12-channel models for recording multiple measurement points. Internal memory stores readings for transfer to a PC using dedicated software.
Measure stationary surface temperatures with Anritsu A Series contact probes. Select the head size, guard and shaft arrangement to suit the measurement point and operating temperature.
Head diameters: 27 mm, 15 mm or 12 mm.
Temperature range: From -50°C, with upper limits of 200 to 800°C depending on construction.
Thermocouple: Type K or Type E.
Configuration: Multiple shaft shapes, lengths, cable and connector options.
Measure small stationary surfaces with Anritsu CS Series micro surface temperature probes. Choose the sensing head, shaft arrangement and connector to suit the measurement point and your thermometer.
Head sizes: 3 mm, 4.2 mm or 6 mm diameter, and 2 × 10 mm rectangular options.
Temperature range: -50 to 400°C, or -50 to 600°C for CS-7 models.
Thermocouple: Type K or Type E.
Configuration: Straight or angled shaft, with grip and gripless options.
Attach an Anritsu MG Series magnetic temperature probe to a suitable stationary metal surface for contact temperature measurement. Built-in magnets hold the sensing head in position, reducing the need to maintain pressure by hand.
Measure moving and rotating surface temperatures with Anritsu U and UX Series contact probes. Select the head, guard or wheel arrangement to suit the surface profile, temperature and operating conditions.
U series: Moving-surface probes with multiple head and mounting configurations.
UX series: Contact-support head that helps maintain contact during measurement.
Thermocouple: Type K or Type E.
Temperature: -50°C to 200°C or 250°C, depending on construction.
Anritsu MW series probes are ideal for measuring the temperatures at the surface of moving wires. Specific components may be combined to customize products for the needs of a customer's specific application.
Measure temperature inside semi-solid materials with Anritsu BT Series needle temperature probes. Choose the needle diameter, length and tip shape to suit the measurement depth and material being tested.
Thermocouple: Type K or Type E.
Temperature range: -200°C to 210°C, 300°C or 500°C, depending on model.
Needle options: Fixed or replaceable construction, with cut or sharp tips.
Spare parts: BTN replacement needles for compatible BT-3 to BT-8 models.
Measure the internal temperature of liquids and semi-solid materials with Anritsu BS Series temperature probes. Choose a fine sleeve-type probe or a grip-type assembly according to the measurement depth, access and handling requirements.
Thermocouple: Type K or Type E.
Probe diameter: 0.9–5.0 mm, depending on model and coating.
Temperature range: -200°C to 200°C, 300°C or 500°C, depending on construction.
Configuration: Select probe length, fluororesin coating, cable and connector.
The Anritsu AR-6500 series combines non-contact infrared measurement with a Type K contact thermometer input. Use a compatible contact probe as a reference for automatic emissivity setting.
Temperature options: -50 to 500°C or 0 to 1200°C, depending on model.
Small measurement area: Defined optics for checking individual surface targets.
Output options: AR-6501 versions provide a 1 mV/°C analog output.
Contact probes: Selected separately to suit the application.
The Anritsu FL Series fiber optic thermometers measure temperature in microwave, high-frequency and high-voltage environments where conventional electrical sensors can be difficult to use.
Model options: FL-2000 with one channel or FL-2400 with four channels.
Probe selection: Dedicated fiber optic probes for different temperatures, materials and operating conditions.
Integration: Analog temperature output and RS-232C communication.
Configuration: Temperature probes are selected separately and are not included with the instrument.
This website uses cookies to ensure you get the best experience on our website