Anritsu ST
Anritsu ST


Type E Model : ST-11E-010-TS1-ANP
Type K Model : ST-11K-010-TS1-ANP

Anritsu ST11
Temp.range : -50 to 210°C
Tolerance : ±2.5°C (at 100°C)
Response time : 2s
Durability : Can not evaluate because of special-application


Type E Model : ST-12E-010-TS1-ANP
Type K Model : ST-12K-010-TS1-ANP

Anritsu ST12
Temp.range : -50 to 210°C
Tolerance : ±2.5°C (at 100°C)
Response time : 8s
Durability : Can not evaluate because of special-application


Type E Model : ST-13E-015-GW1-ANP
Type K Model : ST-13K-015-GW1-ANP

Anritsu ST13
Temp.range : -50 to 400°C
Tolerance : ±2.5°C (at 100°C)
Response time : 2s
Durability : Can not evaluate because of special-application


Type E Model : ST-21E-010-TS1-ANP
Type K Model : ST-21K-010-TS1-ANP

Anritsu ST21
Temp.range : -50 to 210°C
Tolerance : ±2.5°C (at 100°C)
Response time : 2s
Durability : Can not evaluate because of special-application


Type E Model : ST-24E-015-GW1-ANP
Type K Model : ST-24K-015-GW1-ANP

Anritsu ST24
Temp.range : -50 to 400°C
Tolerance : ±2.5°C (at 100°C)
Response time : 8s
Durability : Can not evaluate because of special-application



Type E Model : ST-31E-010-TS1-ANP
Type K Model : ST-31K-010-TS1-ANP

Anritsu ST31
Temp.range : -50 to 210°C
Tolerance : ±2.5°C (at 100°C)
Response time : 2s
Durability : Can not evaluate because of special-application


Type E Model : ST-32E-010-TS1-ANP
Type K Model : ST-32K-010-TS1-ANP

Anritsu ST32
Temp.range : -50 to 210°C
Tolerance : ±2.5°C (at 100°C)
Response time : 8s
Durability : Can not evaluate because of special-application


Type E Model : ST-34E-015-GW1-ANP
Type K Model : ST-34K-015-GW1-ANP

Anritsu ST34
Temp.range : -50 to 400°C
Tolerance : ±2.5°C (at 100°C)
Response time : 8s
Durability : Can not evaluate because of special-application


Type E Model : ST-41E-010-TS1-ANP
Type K Model : ST-41K-010-TS1-ANP

Anritsu ST41
Temp.range : -50 to 210°C
Tolerance : ±2.5°C (at 100°C)
Response time : 2s
Durability : Can not evaluate because of special-application


Type E Model : ST-42E-015-TS1-ANP
Type K Model : ST-42K-015-TS1-ANP

Anritsu ST42
Temp.range : -50 to 210°C
Tolerance : ±2.5°C (at 100°C)
Response time : 8s
Durability : Can not evaluate because of special-application


Type E Model : ST-44E-015-GW1-ANP
Type K Model : ST-44K-015-GW1-ANP

Anritsu ST44
Temp.range : -50 to 400°C
Tolerance : ±2.5°C (at 100°C)
Response time : 8s
Durability : Can not evaluate because of special-application


Type E Model : ST-25E-100-TC1-ANP
Type K Model : ST-25K-100-TC1-ANP

Anritsu ST25
Temp.range : -50 to 210°C
Tolerance : ±2.5°C (at 100°C)
Response time : 2s
Durability : Can not evaluate because of special-application



Model number*1 ST-*1 ST-*2 ST-*3 ST-*4
Thermocouple type Type E or K
Temp. range*2 -50 to 210°C -50 to 210°C Tape length ≦ 150mm : -50 to 400°C
Tape length > 150mm : -50 to 350°C
Tolerance*3 -50°C ≦ t < -40°C ±3.5°C ±3.5°C ±3.5°C ±3.5°C
0°C ±2.5°C ±2.5°C ±2.5°C ±2.5°C
100°C ±2.5°C ±2.5°C ±2.5°C ±2.5°C
200°C ±2.5°C ±2.5°C ±2.5°C ±2.5°C
300°C - - ±2.5°C ±2.5°C
400°C - - ±3.0°C ±3.0°C
Tolerance calculation method
t:Temperature(°C)
At within temperature range
-40°C ≦ t ≦ 400°C:±2.5°C or ± (0.0075 × | t |)°C, whichever is greater
Response time*4 2s 8s 2s 8s
Durability*5 S(Can not evaluate because of special-application)
Repair*6 Non-repairable
Model number*1 ST-25
Thermocouple type Type E or K
Temp. range*2 -50 to 210°C
Tolerance*3 -50°C ≦ t < -40°C ±3.5°C
-40°C ≦ t ≦ 210°C ±2.5°C
Response time*4 2s
Durability*5 S(Can not evaluate because of special-application)
Repair*6 Non-repairable
*1 The asterisk (*) is replaced by the number of the model name you selected. The model number after thermocouple type is omitted.
*2 The operating temperature limit is determined by the allowable temperature limit of the sensor head contacts the measurement target. Note that the operatingtemperature limit is not the same as the allowable temperature limits of the grip, cable, and plug.
*3 Tolerance is defined in the operating temperature range of at the internal temperature with sufficient heat capacity. For tolerance at temperature not listed in the above table, please refer to calculation method of tolerance.
*4 The response time given for our temperature measuring probes is the time required to detect 99% of the true value when measuring the temperature of boiling water or vapor.
*5 Can not evaluate because of special-application.
*6 Please refer to page repair.


Available models:

ST-11K-003~015
ST-12K-003~015
ST-11K-020~050
ST-12K-020~050
ST-11K-060~100
ST-12K-060~100
ST-11K-150
ST-12K-150
ST-11K-200
ST-12K-200
ST-13K-003~015
ST-14K-003~015
ST-13K-020~050
ST-14K-020~050
ST-13K-060~100
ST-14K-060~100
ST-13K-150
ST-14K-150
ST-13K-200
ST-14K-200
ST-21K-003~015
ST-22K-003~015
ST-21K-020~050
ST-22K-020~050
ST-21K-060~100
ST-22K-060~100
ST-21K-150
ST-22K-150
ST-21K-200
ST-22K-200
ST-23K-003~015
ST-24K-003~015
ST-23K-020~050
ST-24K-020~050
ST-23K-060~100
ST-24K-060~100
ST-23K-150
ST-24K-150
ST-23K-200
ST-24K-200


Download



16 other products in the same category: