Anritsu Fine Flexible Internal Probe SF series probes are flexible internal temperature sensors featuring extra-fine thermocouple wires covered with a Teflon-coated sheath.
Specific components may be combined to customize products for the needs of a customer's specific application
Flat Leaf Probe ST Series
:
Anritsu ST series probes are multi-purpose temperature sensors featuring a flexible tape shape. They can be glued to the surfaces of measurement targets for use in a range of applications. Specific components may be combined to customize products for the needs of a customer's specific application.
Type E Model : ST-11E-010-TS1-ANP
|
|
Type E Model : ST-12E-010-TS1-ANP
|
|
Type E Model : ST-13E-015-GW1-ANP
|
|
Type E Model : ST-21E-010-TS1-ANP
|
|
Type E Model : ST-24E-015-GW1-ANP
|
|
Type E Model : ST-31E-010-TS1-ANP
|
|
Type E Model : ST-32E-010-TS1-ANP
|
|
Type E Model : ST-34E-015-GW1-ANP
|
|
Type E Model : ST-41E-010-TS1-ANP
|
|
Type E Model : ST-42E-015-TS1-ANP
|
|
Type E Model : ST-44E-015-GW1-ANP
|
|
Type E Model : ST-25E-100-TC1-ANP
|
|
Model number*1 | ST-*1 | ST-*2 | ST-*3 | ST-*4 | ||
Thermocouple type | Type E or K | |||||
Temp. range*2 | -50 to 210°C | -50 to 210°C | Tape length ≦ 150mm : -50 to 400°C Tape length > 150mm : -50 to 350°C |
|||
Tolerance*3 | -50°C ≦ t < -40°C | ±3.5°C | ±3.5°C | ±3.5°C | ±3.5°C | |
0°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | ||
100°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | ||
200°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | ||
300°C | - | - | ±2.5°C | ±2.5°C | ||
400°C | - | - | ±3.0°C | ±3.0°C | ||
Tolerance calculation method t:Temperature(°C) |
At within temperature range -40°C ≦ t ≦ 400°C:±2.5°C or ± (0.0075 × | t |)°C, whichever is greater |
|||||
Response time*4 | 2s | 8s | 2s | 8s | ||
Durability*5 | S(Can not evaluate because of special-application) | |||||
Repair*6 | Non-repairable |
Model number*1 | ST-25 | |
Thermocouple type | Type E or K | |
Temp. range*2 | -50 to 210°C | |
Tolerance*3 | -50°C ≦ t < -40°C | ±3.5°C |
-40°C ≦ t ≦ 210°C | ±2.5°C | |
Response time*4 | 2s | |
Durability*5 | S(Can not evaluate because of special-application) | |
Repair*6 | Non-repairable |
*1 The asterisk (*) is replaced by the number of the model name you selected. The model number after thermocouple type is omitted. *2 The operating temperature limit is determined by the allowable temperature limit of the sensor head contacts the measurement target. Note that the operatingtemperature limit is not the same as the allowable temperature limits of the grip, cable, and plug. *3 Tolerance is defined in the operating temperature range of at the internal temperature with sufficient heat capacity. For tolerance at temperature not listed in the above table, please refer to calculation method of tolerance. *4 The response time given for our temperature measuring probes is the time required to detect 99% of the true value when measuring the temperature of boiling water or vapor. *5 Can not evaluate because of special-application. *6 Please refer to page repair. |
Available models: ST-11K-003~015 ST-12K-003~015 ST-11K-020~050 ST-12K-020~050 ST-11K-060~100 ST-12K-060~100 ST-11K-150 ST-12K-150 ST-11K-200 ST-12K-200 ST-13K-003~015 ST-14K-003~015 ST-13K-020~050 ST-14K-020~050 ST-13K-060~100 ST-14K-060~100 ST-13K-150 ST-14K-150 ST-13K-200 ST-14K-200 ST-21K-003~015 ST-22K-003~015 ST-21K-020~050 ST-22K-020~050 ST-21K-060~100 ST-22K-060~100 ST-21K-150 ST-22K-150 ST-21K-200 ST-22K-200 ST-23K-003~015 ST-24K-003~015 ST-23K-020~050 ST-24K-020~050 ST-23K-060~100 ST-24K-060~100 ST-23K-150 ST-24K-150 ST-23K-200 ST-24K-200 |