Anritsu BC series probes are internal temperature probes designed to measure the center temperature of food, liquid or semi-solid materials.It is waterproof (IPX5) and can be washed with running water, so you can use it cleanly and hygienically.In order to prevent contamination, the probes designed to prevent the parts falling off.
Depending on the application, it is possible to combine the outside diameter, length, presence of coating of the protective pipe and plug shape.
Micro Sensor Probe CS Series
:
Anritsu CS series probes are small surface temperature sensors designed to measure the temperature of stationary surface.Specific components may be combined to customize products for the needs of a customer's specific application.
Type E Model:CS-01E-010-1-TC1-ANP
|
|
Type E Model:CS-03E-010-1-TC1-ANP
|
|
Type E Model:CS-11E-010-1-TC1-ANP
|
|
Type E Model:CS-13E-010-1-TC1-ANP
|
|
Type E Model:CS-21E-010-1-TC1-ANP
|
|
Type E Model:CS-36E-010-1-TC1-ANP
|
|
Type E Model:CS-73E-010-1-TC1-ANP
|
|
Model number*1 | CS-0* | CS-1* CS-2* CS-3* |
CS-7* | |
Thermocouple type | Type E or K | |||
Temp. range*2 | -50 to 400°C | -50 to 600°C | ||
Tolerance*3 | -50°C ≦ t < 0°C | - | ±2.5°C | ±2.5°C |
0°C ≦ t ≦ 100°C | ±3.0°C | ±2.5°C | ±2.5°C | |
100°C < t ≦ 200°C | ±5.0°C | ±3.1°C | ±3.1°C | |
200°C < t ≦ 300°C | ±7.5°C | ±5.0°C | ±5.0°C | |
300°C < t ≦ 400°C | ±10.0°C | ±6.3°C | ±6.3°C | |
400°C < t ≦ 500°C | - | - | ±8.0°C | |
500°C < t ≦ 600°C | - | - | ±13.0°C | |
Response time*4 | 3s | 2s | ||
Durability*5 | A(More than 50,000 contacts) | |||
Pipe material | Stainless(SUS304) | |||
Grip material | Phenol Resin | |||
Repair*6 | Repairable |
*1 The asterisk (*) is replaced by the number of the model name you selected. The model number after thermocouple type is omitted. *2 The operating temperature limit is determined by the allowable temperature limit of the sensor head contacts the measurement target. Note that the operatingtemperature limit is not the same as the allowable temperature limits of the grip, cable, and plug. *3 Tolerance is available at -50°C or above within the operating temperature on a stationary flat and smooth metal surface. *4 The response time is the time required to detect 99% of the true value on a flat and smooth metal surface. *5 Number of contacts enabling measurement within the tolerance range on a flat and smooth metal surface at a temperature of 300°C. *6 Please refer to page repair. |
Available models: CS-01K-010-0-TS1-*** CS-01K-015-0-TS1-*** CS-01K-005-1-TC1-*** CS-01K-010-1-TC1-*** CS-01K-015-1-TC1-*** CS-03K-010-0-TS1-*** CS-03K-015-0-TS1-*** CS-03K-005-1-TC1-*** CS-03K-010-1-TC1-*** CS-03K-015-1-TC1-*** CS-11K-010-0-TS1-*** CS-11K-015-0-TS1-*** CS-11K-005-1-TC1-*** CS-11K-010-1-TC1-*** CS-11K-015-1-TC1-*** CS-13K-010-0-TS1-*** CS-13K-015-0-TS1-*** CS-13K-005-1-TC1-*** CS-13K-010-1-TC1-*** CS-13K-015-1-TC1-*** CS-21K-005-0-TS1-*** CS-21K-010-0-TS1-*** CS-21K-015-0-TS1-*** CS-21K-005-1-TC1-*** CS-21K-010-1-TC1-*** CS-21K-015-1-TC1-*** CS-23K-005-0-TS1-*** CS-23K-010-0-TS1-*** CS-23K-015-0-TS1-*** CS-23K-005-1-TC1-*** CS-23K-010-1-TC1-*** CS-23K-015-1-TC1-*** CS-31K-015-0-TS1-*** CS-31K-010-1-TC1-*** CS-31K-015-1-TC1-*** CS-33K-010-0-TS1-*** CS-33K-015-0-TS1-*** CS-33K-005-1-TC1-*** CS-33K-010-1-TC1-*** CS-33K-015-1-TC1-*** CS-36K-010-0-TS1-*** CS-36K-015-0-TS1-*** CS-36K-005-1-TC1-*** CS-36K-010-1-TC1-*** CS-36K-015-1-TC1-*** |