Anritsu MW


Type E Model : MW-31E-TC1-ANP
Type K Model : MW-31K-TC1-ANP

Anritsu MW31
Temp.range : -50 to 250°C
Tolerance : ±2.5°C (at 100°C surface)
Response time : 5s
Durability : Can not evaluate because of special-application


Type E Model : MW-32E-TC1-ANP
Type K Model : MW-32K-TC1-ANP

Anritsu MW32
Temp.range : -50 to 250°C
Tolerance : ±2.5°C (at 100°C surface)
Response time : 5s
Durability : Can not evaluate because of special-application


Type E Model : MW-33E-TC1-ANP
Type K Model : MW-33K-TC1-ANP

Anritsu MW33
Temp.range : -50 to 250°C
Tolerance : ±2.5°C (at 100°C surface)
Response time : 5s
Durability : Can not evaluate because of special-application


Type E Model : MW-44E-TC1-ANP
Type K Model : MW-44K-TC1-ANP

Anritsu MW34
Temp.range : -50 to 250°C
Tolerance : ±2.5°C (at 100°C surface)
Response time : 5s
Durability : Can not evaluate because of special-application


Type E Model : MW-45E-TC1-ANP
Type K Model : MW-45K-TC1-ANP

Anritsu MW45
Temp.range : -50 to 250°C
Tolerance : ±2.5°C (at 100°C surface)
Response time : 5s
Durability : Can not evaluate because of special-application


Type E Model : MW-46E-TC1-ANP
Type K Model : MW-46K-TC1-ANP

Anritsu MW46
Temp.range : -50 to 250°C
Tolerance : ±2.5°C (at 100°C surface)
Response time : 5s
Durability : Can not evaluate because of special-application



Model number*1 MW-3* MW-4*
Thermocouple type Type E or K
Temp. range*2 -50 to 250°C
Tolerance*3 0°C ≦ t ≦ 200°C ±2.5°C ±2.5°C
200°C < t ≦ 250°C ±3.0°C ±3.0°C
Response time*4 5s
Durability*5 S(Can not evaluate because of special-application)
Roller material Teflon
Guard material Teflon
Roller setting plate material Stainless(SUS304)
Pipe material Stainless(SUS316)
Grip material Polyacetal
Repair*6 Repairable


*1 The asterisk (*) is replaced by the number of the model name you selected. The model number after thermocouple type is omitted.
*2 The operating temperature limit is determined by the allowable temperature limit of the sensor head contacts the measurement target. Note that the operatingtemperature limit is not the same as the allowable temperature limits of the grip, cable, and plug.
*3 Tolerance is available at 0°C or above within the operating temperature on a stationary flat and smooth metal surface.
*4 The response time is the time required to detect 99% of the true value on a flat and smooth metal surface.
*5 Can not evaluate because of special-application
*6 Please refer to page repair.


Available models:

MW-11K
MW-12K
MW-13K
MW-24K
MW-25K
MW-26K


Download