Thermologger AM-9000 series
画像

AM-9000 series is a temperature logger that can record the measured data.
Data held in memory can then be transferred to a PC via dedicated software for later analysis or other use.

・Thermocouple type fixed type / multi-input type, 6ch / 12ch lineup selectable.
・USB Communication
・The recorded data can be easily transferred to PC with the dedicated analysis software AMS-950 (sold separately).
・Dual power supply system with dry batteries and AC adapter.

AM9000

AM-9000E / AM-9000K

Thermocouple fixed type・6ch type



画像

AM-9100E / AM-9100K

Thermocouple fixed type・12ch type



画像

AM-9200

Multi-input type・6ch type



画像

AM-9300

Multi-input type・12ch type

Model AM-9000※ AM-9100※ AM-9200 AM-9300
Channel 6CH 12CH 6CH 12CH
Input connector ANP connector (same type thermocouple) ANP connector (both poles are coper)
Input type Temperature: E, K, J, T, R by selected model *2 Temperature:Multi-input (E・K・J・T・R)
DC Voltage:V DC Voltage:V
Measurement range Temperature: TABLE Ⅰ
DC Voltage : ±20.000V
Resolution Temperature: 0.1℃/1℃
DC Voltage : 0.001V
Measurement accuracy Temperature: TABLE Ⅱ
DC Voltage : ±(0.05% of reading +0.003V)
Memory capacity 120,000 data
Interface USB2.0(microーB)
Dimensions 92×155×36 96 ×160 ×60 92×155×36 96 ×160×60
(W)×(H)×(D)mm *Protruded parts excluded
Weight(Including dry batteries) approx.380g approx.480g approx.410g approx.540g
Reference junction
compensation accuracy
±0.3℃*3 ±0.5℃*3
Temperature coefficient ±(0.04×Δt℃)*4
Time interval less than 1s : 0.1s ~ 0.99s less than 1s : 0.2s ~ 0.99s less than 1s : 0.2s ~ 0.99s
Over 1s : 1s ~ 99m 59s Over 1s : 1s ~ 99m 59s Over 1s : 1s ~ 99m 59s
Signal source resistance 500Ω or less (measurement interval 1 second or more)/100Ω or less (measurement interval less than 1 second)
Safe excitation voltage Between input pins on same channels :±30VDC
Between input pins on adjacent channels : 150Vp-p
Linearlizer Digital Linealizer method (Compliant with JIS C1602-2015)
Display Graphic liquid crystal display, 128×64 dots
Environment operational
Environment storage
Operation : 0〜40℃、15〜80%RH (Non condensing)  
Storage : -10〜50℃、10〜85%RH (Non condensing)
Power supply 4 AA Alkaline batteries(Supplied accessories) or AC-Adaptor(Optional accessories)
Supplied accessories Manual, Test report, Softcase, Communications cable, 4 AA Alkaline batteries
Optional accessories Special data analysis software, AC-Adaptor, Carrying case
Compatible standards CE Marking, RoHS2
The selected thermocouple type (E・K・J・T・R) is entered in ※ of the model name.
*1 Thermocouple type (E・K・J・T・R)
*2 Type J・T・R are optional
*3 At 25℃±10℃
*4 When the ambient temperature is other than from 15℃ to 35℃, "the excess temperature from the ambient temperature Δt℃" x 0.04 is added to the measurement accuracy.

TABLE Ⅰ : Measurement Range

Thermocouple type Measurement range
E -200 to 800°C
K -200 to 1370°C
J -200 to 1100°C
T -200 to 400°C
R 0 to 1760°C

TABLE Ⅱ : Measurement accuracy

Thermocouple type Accuracy compensation range Measurement accuracy
AM-9000※/AM-9100※ AM-9200/AM-9300
E,K,J,T -200.0~-100.1℃ ±1.0℃ ±1.5℃
-100.0~-0.1℃ ±0.5℃ ±1.0℃
0.0~200.0℃ ±0.3℃ ±0.5℃
200.1~500.0℃ ±0.5℃ ±0.7℃
500.1℃以上 ±0.7℃ ±1.0℃
R 0.0℃~500.0℃ ±1.5℃ ±2.0℃
500.1℃以上 ±2.0℃ ±2.5℃

*If the measurement interval is less than 1 sec, add ± 0.5 ℃ at type E ・ K ・ J ・ T and add ± 1.0℃ at type R

TABLEⅢ 12ch model standard time for continuous use (at 25 ℃, using alkaline AA batteries)

Setting interval 0.2sec 1sec 10sec
AM-9000 Series approx. 50 hours approx. 55 hours approx. 140 hours

* If the number of used channels is less than 12, the usable time will be longer.