Model |
AM-9000※ |
AM-9100※ |
AM-9200 |
AM-9300 |
Channel |
6CH |
12CH |
6CH |
12CH |
Input connector |
ANP connector (same type thermocouple) |
ANP connector (both poles are coper) |
Input type |
Temperature: E, K, J, T, R by selected model *2 |
Temperature:Multi-input (E・K・J・T・R) |
DC Voltage:V |
DC Voltage:V |
Measurement range |
Temperature: TABLE Ⅰ |
DC Voltage : ±20.000V |
Resolution |
Temperature: 0.1℃/1℃ |
DC Voltage : 0.001V |
Measurement accuracy |
Temperature: TABLE Ⅱ |
DC Voltage : ±(0.05% of reading +0.003V) |
Memory capacity |
120,000 data |
Interface |
USB2.0(microーB) |
Dimensions |
92×155×36 |
96 ×160 ×60 |
92×155×36 |
96 ×160×60 |
(W)×(H)×(D)mm *Protruded parts excluded |
Weight(Including dry batteries) |
approx.380g |
approx.480g |
approx.410g |
approx.540g |
Reference junction compensation accuracy |
±0.3℃*3 |
±0.5℃*3 |
Temperature coefficient |
±(0.04×Δt℃)*4 |
Time interval |
less than 1s : 0.1s ~ 0.99s |
less than 1s : 0.2s ~ 0.99s |
less than 1s : 0.2s ~ 0.99s |
Over 1s : 1s ~ 99m 59s |
Over 1s : 1s ~ 99m 59s |
Over 1s : 1s ~ 99m 59s |
Signal source resistance |
500Ω or less (measurement interval 1 second or more)/100Ω or less (measurement interval less than 1 second) |
Safe excitation voltage |
Between input pins on same channels :±30VDC |
Between input pins on adjacent channels : 150Vp-p |
Linearlizer |
Digital Linealizer method (Compliant with JIS C1602-2015) |
Display |
Graphic liquid crystal display, 128×64 dots |
Environment operational Environment storage |
Operation : 0〜40℃、15〜80%RH (Non condensing) |
Storage : -10〜50℃、10〜85%RH (Non condensing) |
Power supply |
4 AA Alkaline batteries(Supplied accessories) or AC-Adaptor(Optional accessories) |
Supplied accessories |
Manual, Test report, Softcase, Communications cable, 4 AA Alkaline batteries |
Optional accessories |
Special data analysis software, AC-Adaptor, Carrying case |
Compatible standards |
CE Marking, RoHS2 |
The selected thermocouple type (E・K・J・T・R) is entered in ※ of the model name. *1 Thermocouple type (E・K・J・T・R) *2 Type J・T・R are optional *3 At 25℃±10℃ *4 When the ambient temperature is other than from 15℃ to 35℃, "the excess temperature from the ambient temperature Δt℃" x 0.04 is added to the measurement accuracy. |
TABLE Ⅰ : Measurement Range
Thermocouple type |
Measurement range |
E |
-200 to 800°C |
K |
-200 to 1370°C |
J |
-200 to 1100°C |
T |
-200 to 400°C |
R |
0 to 1760°C |
TABLE Ⅱ : Measurement accuracy
Thermocouple type |
Accuracy compensation range |
Measurement accuracy |
AM-9000※/AM-9100※ |
AM-9200/AM-9300 |
E,K,J,T |
-200.0~-100.1℃ |
±1.0℃ |
±1.5℃ |
-100.0~-0.1℃ |
±0.5℃ |
±1.0℃ |
0.0~200.0℃ |
±0.3℃ |
±0.5℃ |
200.1~500.0℃ |
±0.5℃ |
±0.7℃ |
500.1℃以上 |
±0.7℃ |
±1.0℃ |
R |
0.0℃~500.0℃ |
±1.5℃ |
±2.0℃ |
500.1℃以上 |
±2.0℃ |
±2.5℃ |
*If the measurement interval is less than 1 sec, add ± 0.5 ℃ at type E ・ K ・ J ・ T and add ± 1.0℃ at type R
TABLEⅢ 12ch model standard time for continuous use (at 25 ℃, using alkaline AA batteries)
Setting interval |
0.2sec |
1sec |
10sec |
AM-9000 Series |
approx. 50 hours |
approx. 55 hours |
approx. 140 hours |
* If the number of used channels is less than 12, the usable time will be longer.
|