Output |
Voltage (0 - 1V) |
Voltage (0 - 100mV) |
Current (4 - 20mA) |
Digital (RS-485) |
Cat. No. |
8920-01 |
8920-02 |
8920-03 |
8920-04 |
Model |
SK-RHC-V |
SK-RHC-V |
SK-RHC-I |
SK-RHC-C |
Measuring range |
Depends on the probe connected |
Display range |
Temperature : -15 to 65.0°C Humidity : 5 to 99.9%rh |
Measuring Accuracy |
Depends on the probe connected |
Output accuracy |
Temperature :±0.3°C Humidity:±0.3%rh |
Temperature :±1.0°C Humidity :±1.0%rh |
- - - |
Resolution |
Temperature: 0.1°C (at higher than -9.9°C) 1°C (at other range) Humidity: 0.1%rh (at higher than 15%rh) 1%rh(at other range) |
Display accuracy |
Temperature :±(0.1+1digit)°C Humidity :±(0.1+1digit)%rh |
Output |
Temperature |
-10 to 60°C / -100mV to 600mV |
-10 to 60°C / -10mV to 60mV |
-15 to 65°C / 4 to 20mA |
- - - |
Humidity |
0 to 100%rh / 0 to 1000mV |
0 to 100%rh / 0 to 100mV |
0 to 100%rh / 4 to 20mA |
- - - |
Output Impedance |
500Ω |
- - - |
RS-485 |
- - - |
Bit/sec: 9600 Data bit: 8 Stop bit: 1 Parity check: non |
Power requirement |
12 to 24VDC or AC adapter (9VDC / 500mA) |
Functions |
Upper/lower limit output (relay contact) (Max. rate of alarm output: Voltage resistance: 48VAC/DC continuous load current: 1A) Sampling( switchable at 1 sec. and 10 sec.) |
Materials |
Main body: ABS resin ,Display: Acryl resin |
Dimensions/Weight |
118(W) x 100(H) x 42(D)mm, approx. 220g |
Accessories |
One fixing screw to fasten the probe |