Principle of Operation

Monnit ALTA Wireless Thermocouple is available with either a hardwired thermocouple or a K-Type connector (for supporting various thermocouple types and ranges) to measure high temperature applications. It is programmed to sleep for a user-given time interval (heartbeat) and then wakeup, send power to the thermocouple and wait for it to stabilize, and convert the analog data, mathematically compute the temperature and transmit the data to the gateway. To stay within the abilities of the processor, the temperature is computed off a data table provided by the manufacturer



Example Interfacing

  • Chimmey/Flue Temperature Monitoring
  • Kiln TEmprature Monitoring
  • High Temperature Food Monitoring



Features of Monnit ALTA Sensors

  • Wireless range of 1,200+ feet through 12+ walls *
  • Frequency-Hopping Spread Spectrum (FHSS)
  • Improved interference immunity
  • Improved power management for longer battery life **
  • Encrypt-RF ® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
  • Datalogs 2000 to 4000 readings if gateway connection is lost (non-volatile flash, persists through the power cycle):
  • 10-minute heartbeats = ~ 22 days - 2-hour heartbeats = ~ 266 days
  • Over-the-air updates (future proof)
  • Free iMonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email Wireless Range Comparison

*Actual range may vary depending on environment.

**Battery life is determined by sensor reporting frequency and other variables. Other power options are also available.







ALTA Commercial AA Wireless Thermocouple Sensor

Technical Specifications

ALTA Commercial AA Wireless Thermocouple Sensor

Supply Voltage 2.0-3.8 VDC  (3.0-3.8 VDC using power supply) *
Current Consumption 0.2 µA (sleep mode), 0.7 µA (RTC sleep), 570 µA (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX mode) 
Operating temperature range (board circuitry and batteries)  -18°C to 55°C (0°F to 130°F) using alkaline
-40°C to 85°C (-40°F to 185°F) using lithium **
Optimal battery temperature range (batteries)  +10°C to +50°C (+50°F to +122°F) 
Thermocouple connection options  6 ft hardwired probe/5 ft K-type connector
Hardwired thermocouple probe accuracy above 0°C ± 2.2°C or 0.75% (whichever is greater)
Hardwired thermocouple probe accuracy below 0°C                            ± 2.2°C or 0.75% (whichever is greater)
Datalogging Up to 3200 sensor messages
Wireless Range 1,200+ ft non-line-of-sight 
Security Encrypt-RF ® (256-bit key exchange and AES-128 CTR) 
Weight 4.7 ounces 
Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. 868 and 433 MHz product tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950

* Hardware cannot withstand negative voltage. Please take care when connecting a power device.

** At temperatures above 100°C, it is possible for the board circuitry to lose programmed memory. 



ALTA Commercial Coin Cell Thermocouple Humidity Sensor

Technical Specifications

ALTA Commercial AA Wireless Thermocouple Sensor

Supply Voltage 2.0-3.8 VDC (3.0-3.8 VDC using power supply) *
Current Consumption 0.2 µA (sleep mode), 0.7 µA (RTC sleep), 570 µA (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX mode) 
Operating temperature range (board circuitry and coin cell)  -7°C to +60°C (20°F to +140°F) **
Optimal battery temperature range (coin cell)  +10°C to +45°C (+50°F to +113°F)
Accuracy  ± 2% under normal conditions (0%-80% RH) **
Thermocouple connection options 6 ft hardwired probe/5 ft K-type connector
Hardwired thermocouple probe accuracy above 0°C                            ± 2.2°C or 0.75% (whichever is greater)
Hardwired thermocouple probe accuracy below 0°C ±2.2°C or 0.75% (whichever is greater)
Datalogging Up to 3200 sensor messages
Wireless Range 1,200+ ft non-line-of-sight 
Security Encrypt-RF ® (256-bit key exchange and AES-128 CTR) 
Weight 1.7 ounces 
Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. 868 and 433 MHz product tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950

* Hardware cannot withstand negative voltage. Please take care when connecting a power device.

** At temperatures above 100°C, it is possible for the board circuitry to lose programmed memory.



ALTA Industrial Wireless Thermocouple Sensor

Technical Specifications

ALTA Commercial AA Wireless Thermocouple Sensor

Supply Voltage 2.0-3.8 VDC (3.0-3.8 VDC using power supply) *
Current Consumption 0.2 µA (sleep mode), 0.7 µA (RTC sleep), 570 µA (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX mode) 
Operating temperature range (board circuitry and battery)  -40°C to +85°C (-40°F to +185°F) **
Thermocouple connection options 6 ft hardwired probe/5 ft K-type connector
Hardwired thermocouple probe accuracy above 0°C ± 2.2°C or 0.75% (whichever is greater)
Hardwired thermocouple probe accuracy below 0°C                            ± 2.2°C or 2.0% (whichever is greater)
Datalogging Up to 3200 sensor messages
Wireless Range 1,200+ ft non-line-of-sight 
Security Encrypt-RF ® (256-bit key exchange and AES-128 CTR) 
Weight 5.7 ounces 
Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. 868 and 433 MHz product tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950

* Hardware cannot withstand negative voltage. Please take care when connecting a power device.

** At temperatures above 100°C, it is possible for the board circuitry to lose programmed memory



Download