- Out-of-Stock
Measure temperature inside semi-solid materials with Anritsu BT Series needle temperature probes. Choose the needle diameter, length and tip shape to suit the measurement depth and material being tested.
Check temperatures below the surface of semi-solid materials using Anritsu BT Series needle temperature probes. The range offers different needle diameters, insertion lengths and tip shapes, allowing the probe to be selected around the sample and measurement depth.
Choose a fixed-needle assembly or a model with replaceable needles. For repeat measurements where spare sensing needles are needed, specify the compatible BTN replacement needle together with the probe.
Anritsu BT needle probes for internal temperature measurement in semi-solid materials.
Both Type E and Type K versions are available. Within each pair, the final digit identifies the tip: 1 = cut and 2 = sharp.
| Models | Needle diameter × length | Temperature range | Response | Replaceable needle |
|---|---|---|---|---|
| BT-11 / BT-12 | 0.9 × 15 mm | -200 to 210°C | 0.5 s | No |
| BT-21 / BT-22 | 1.5 × 30 mm | -200 to 300°C | 1.5 s | No |
| BT-31 / BT-32 | 1.6 × 30 mm | -200 to 300°C | 1.5 s | Yes |
| BT-41 / BT-42 | 1.6 × 40 mm | -200 to 300°C | 1.5 s | Yes |
| BT-51 / BT-52 | 1.6 × 50 mm | -200 to 300°C | 1.5 s | Yes |
| BT-61 / BT-62 | 1.6 × 60 mm | -200 to 300°C | 1.5 s | Yes |
| BT-71 / BT-72 | 1.6 × 70 mm | -200 to 300°C | 1.5 s | Yes |
| BT-81 / BT-82 | 5.0 × 75 mm | -200 to 500°C | 3 s | Yes |
| BT-91 / BT-92 | 5.0 × 100 mm | -200 to 500°C | 3 s | No |
Temperature limits: The listed range applies to the sensing portion. The handle, cable and connector have separate operating limits.
Select the needle dimensions, tip shape, thermocouple, cable and plug.
The following table retains the full Type E and Type K configurations previously listed on this page.
| Probe | Type E model | Type K model |
|---|---|---|
BT-31 ![]() |
BT-31E-TC1-ANP | BT-31K-TC1-ANP |
BT-92 ![]() |
BT-92E-TC1-ANP | BT-92K-TC1-ANP |
BT-72 ![]() |
BT-72E-TC1-ANP | BT-72K-TC1-ANP |
BT-22 ![]() |
BT-22E-TC1-ANP | BT-22K-TC1-ANP |
BT-82 ![]() |
BT-82E-TC1-ANP | BT-82K-TC1-ANP |
BT-11 ![]() |
BT-11E-TC1-ANP | BT-11K-TC1-ANP |
All Type K references from the existing listing are retained below. BT references identify probe configurations; BTN references identify replacement needles rather than complete probes.
| Needle size | Cut-tip probe | Sharp-tip probe | Cut-tip spare | Sharp-tip spare |
|---|---|---|---|---|
| 0.9 × 15 mm | BT-11K | BT-12K | Not replaceable | Not replaceable |
| 1.5 × 30 mm | BT-21K | BT-22K | Not replaceable | Not replaceable |
| 1.6 × 30 mm | BT-31K | BT-32K | BTN-31K | BTN-32K |
| 1.6 × 40 mm | BT-41K | BT-42K | BTN-41K | BTN-42K |
| 1.6 × 50 mm | BT-51K | BT-52K | BTN-51K | BTN-52K |
| 1.6 × 60 mm | BT-61K | BT-62K | BTN-61K | BTN-62K |
| 1.6 × 70 mm | BT-71K | BT-72K | BTN-71K | BTN-72K |
| 5.0 × 75 mm | BT-81K | BT-82K | BTN-81K | BTN-82K |
| 5.0 × 100 mm | BT-91K | BT-92K | Not replaceable | Not replaceable |
Supply configuration: The existing listing specifies replaceable-needle probe sets with a grip and five needles, and replacement needles in five-piece sets. Confirm pack contents and quantity when requesting a quotation.
Spare-needle matching: Provide the original BT model, thermocouple type and required tip shape. Type E spare needles are also available; confirm the exact BTN reference for your assembly.
| Temperature | BT-1 models | BT-2 to BT-7 models | BT-8 and BT-9 models |
|---|---|---|---|
| 0°C | ±2.5°C | ±2.5°C | ±2.5°C |
| 100°C | ±2.5°C | ±2.5°C | ±2.5°C |
| 200°C | ±2.5°C | ±2.5°C | ±2.5°C |
| 300°C | Outside range | ±2.5°C | ±2.5°C |
| 400°C | Outside range | Outside range | ±3.0°C |
| 500°C | Outside range | Outside range | ±3.8°C |
For temperatures from -40°C upward, within the selected model’s operating range, tolerance is the greater of ±2.5°C or ±0.75% of the absolute temperature in °C. For sub-zero applications, specify the working temperature and required uncertainty so the applicable tolerance can be confirmed.
Manufacturer tolerance is established under internal-temperature measurement conditions with sufficient heat capacity. Response times represent 99% response in boiling water or vapour; actual response depends on the sample and insertion conditions.
| Item | Details |
|---|---|
| Needle material | SUS304 stainless steel. |
| Grip materials | Phenolic resin, aluminium or nylon resin, depending on model. |
| BT-1 durability classification | C: more than six months under the manufacturer’s classification. |
| BT-2 to BT-8 durability classification | S: no general rating because use is application-specific. |
| BT-9 durability classification | B: more than one year under the manufacturer’s classification. |
| Repairability | Listed as non-repairable. Designated models allow needle replacement. |
Durability classifications are not service-life guarantees. Describe the sample hardness and insertion method when selecting a probe. Avoid using the needle to lever or force apart the material.
Measurement depth: Choose a needle that reaches the required location while keeping the handle clear of the sample.
Repeated testing: If replacement needles are required, select a compatible BT-3 to BT-8 model and include the appropriate BTN spare sets.
Instrument compatibility: Match Type E or Type K to the thermometer or logger input. Confirm the cable length and plug; the complete references above use an ANP miniature connector.
For other liquid and semi-solid measurement configurations, compare the Anritsu BS Series internal temperature probes.
Contact us for pricing and availability. Please include: