Overview

Item Model
ND05 -
TATAAA

ND05-
PATAAC
ND05-
NATAAC
ND10-
TATAAA
ND10-
PATAAA
ND10-
NATAAA
ND20-
PATAAA
ND20-
NATAAA
Flow-rate range 0.3 - 3 L/min 1.0 - 10L/min 1.5 - 20L/min 3.0 - 60L/min
Accuracy
(Standard installation position)
±2% (RS)
Pulse unit 2.5mL/p 7.69mL/p 25mL/p
Pressure drop 12 kPa or less
(At 3L/min)
15 kPa or less
(At 10L/min)
20 kPa or less
(At 20L/min)
60 kPa or less
(At 60L/min)
Fluid temperature range 0 to +60°C 0 to +70°C 0 to +60°C 0 to +70°C 0 to +60°C 0 to +70°C
Connection R 1/2 R 3/4
Weight Approx.150g Approx.120g Approx.360g


Common Specification

Maximum working pressure 1MPa or less with a fluid temperature of +20°C
Viscosity 0.5 to 1.5 mPa·s
Output signal Open collector pulse
4-wires, Lead-wire length approx. 600mm
Duty ratio 3/7 < A/B < 7/3
Impressed voltage range 3 to 15 V DC
Ambient temperature -20° to +80° (Dew condensation must be avoided)


Model ND
Fixed / Portable Fixed
Tolerance Maximum temperature: up to 70 deg C
Maximum pressure: 1Mpa
Measurement Range from 0.3 to 60 L/min
Connection R1/2, R3/4
Accuracy ± 2% RS
Output Pulse


Download