Ammonia Description

Ammonia transmitter E2618-NH3-E is a member of new PluraSens® family of multifunctional measurement instruments.

The instrument is intended for leakage control in refrigeration facilities, warehouses etc. It is not recommended to use the device in spaces with constantly high ammonia concentration such as cattle, pig and poultry livestock houses, since it shortens the sensor lifetime. 

The instrument utilises a fully calibrated and temperature compensated electrochemical gas sensor with excellent repeatability, stability and long lifetime.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.

Ammonia Technical Data
Calibration ammonia NH3
Sensor type electrochemical
Sampling method diffusion
Detection range 0...100 ppm NH3
0...300 ppm NH3
0...1000 ppm NH3
0...5 000 ppm NH3
up to 10000 ppm on request
Resolution 1 ppm NH3
Sensor lifetime > 2 years
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions -40...+50°C, -30...+50°C (for 0...5 000 ppm),
15...90 %RH
Carbon Dioxide CO2 Description

Carbon Dioxide transmitter E2618-CO2 is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include HVAC and air quality control in public, office and industrial buildings, greenhouses, underground parkings, boiler houses, and other confined spaces, where potentially toxic concentration of carbon dioxide can accumulate.

The instrument utilises a fully calibrated and temperature compensated photoacoustic or optical NDIR gas sensor with excellent repeatability, stability and long lifetime. Ambient pressure compensation (in the range 0,5...2 bar of absolute pressure) is available as an option.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.

Carbon Dioxide CO2 Technical Data
Calibration carbon dioxide CO2
Sensor type photoacoustic
optical NDIR
Sampling method diffusion
Detection range 0...10 000 ppm (10K) CO2
0...40 000 ppm (40K) CO2
0...5 %vol (50KN) CO2
up to 100 %vol CO2 on request
Resolution 1 ppm for 10K
10 ppm for 40K
0.01%vol for 50KN
Sensor lifetime up to 10 years for 10K/40K
up to 5 years for 50KN
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions -40...+60 °C, 0...100 %RH
Carbon Monoxide CO Description

Carbon monoxide transmitter E2618-CO is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include underground parkings, boiler houses, kitchens, and other confined spaces, where potentially toxic concentration of carbon monoxide can accumulate.

The instrument utilises a fully calibrated and temperature compensated electrochemical gas sensor with excellent repeatability, stability and long lifetime.

Analog output and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the transmitter to safety or building automation systems.

Carbon Monoxide CO Technical Data
Calibration carbon monoxide CO
Sensor type electrochemical
Sampling method diffusion
Detection range 0...300 ppm CO
0...1000 ppm CO
Resolution 1 ppm CO
Sensor lifetime > 10 years
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions -20...+50 °C, 15...90 %RH
Hydrogen Sulfide H2S Description

Hydrogen Sulfide transmitter E2618-H2S is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include sewerage systems, labs, industrial premises and other confined spaces, where potentially toxic concentration of hydrogen sulfide can accumulate.

The instrument utilises a fully calibrated and temperature compensated electrochemical gas sensor with excellent repeatability, stability and long lifetime.

wo analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.

Hydrogen Sulfide H2S Technical Data
Calibration hydrogen sulfide H2S
Sensor type electrochemical
Sampling method diffusion
Detection range 0...100 ppm H2S
0...2000 ppm H2S
other ranges on request
Resolution 1 ppm H2S
Sensor lifetime > 2 years
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions -30...+50 °C, 15...90 %RH for 100 ppm range
-40...+50 °C, 15...90 %RH for 2000 ppm range
Oxygen O2 Description

Oxygen transmitter E2618-O2 is a member of new PluraSens® family of multifunctional measurement instruments.

The instrument may be used to prevent critical decrease of O2 concentration as well as to control the absence of the oxygen in gas mixtures.

The instrument utilises a fully calibrated and temperature compensated gas sensor with excellent repeatability, stability and long lifetime. 

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the transmitter to safety or building automation systems.

Oxygen O2 Technical Data
Calibration oxygen O2
Sensor type electrochemical
Sampling method diffusion
Detection range 0...25 %vol O2
Resolution 0,01 %vol O2
Sensor lifetime > 2 years
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions -30...+50 °C, 15...90 %RH
Refrigerant HFC Description

Refrigerant transmitter E2618-HFC is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include cold storage warehouses, skating arenas, and other areas, where leakages of halocarbon refrigerants are possible.

The instrument utilises a fully calibrated metal-oxide semiconductor gas sensor with excellent repeatability, stability and long lifetime. The sensor is highly sensitive to a wide range of CFC, HFC and HFO compounds, including R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234yf, R-1234ze and similar.

For demanding applications, a NDIR sensor is available on request.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.
Refrigerant HFC Technical Data
Detected gases R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234yf, R-1234ze etc
Default calibration R-404a
Sensor type metal-oxide semiconductor
optical NDIR on demand
Sampling method diffusion
Detection ranges 0...1000 ppm halocarbon gas
0...2500 ppm halocarbon gas
Resolution 1 ppm halocarbon gas
Sensor lifetime >5 years
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions -30...+60 °C, 0...95 %RH

Combustible Gas LEL Description

Combustible gas detector E2618-LEL is a member of PluraSens® family of multifunctional measurement instruments. The device exhibits sensitivity to hydrogen, methane, acetylene, propane and butane

Applications include underground parkings, boiler houses, battery charging rooms, kitchens, and other confined spaces, where potentially explosive concentration of combustible gases can accumulate.

The instrument utilises fully calibrated metal-oxide semiconductor or pellistor gas sensors with excellent repeatability, stability and long lifetime.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the transmitter to safety or building automation systems.

Combustible Gas LEL Technical Data
Detected gases hydrogen, methane, acetylene, propane, butane
Default calibration methane CH4
Sensor type metal-oxide semiconductor (MOS)
pellistor (catalytic bead) on demand
Sampling Diffusion
Detection range 0...100% LEL
Resolution 0,1 / 1 % LEL
Sensor lifetime >5 years (MOS)
>3 years (pellistor)
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions 0...95 %RH,
-40...+70 °C (MOS)
-10...+50 °C (pellistor)