RCM Direct Reading Differential Pressure Flowmeter for Liquid & Gas
There are 11 products.
Active filters
Sekonic Digital Thermohygrograph ST50M with memory card recording.
It records on chart paper and/or memory card. The data is ready to export to Excel (.csv) format.
Installation of the Tokico emergency shutoff valve is required at various industrial equipments by the High Pressure Gas Safety Law and the Fire Defense Law.
In the MB series of emergency shutoff valve, CO2 gas cartridge with high initial torque is adopted as drive source, and ball valve making smooth movement is adopted at the valve part.
It shutoffs urgently or opens the pipelines of various fluids and is most suitable as safety disaster prevention equipment which prevents second disaster from occurring.
Evikon Gas Transmitter E2618 series is intended for measurement of gases with high accuracy
Features:
- Industrial enclosure with IP65 protection
- Attached or remote sensor options
- Two analog outputs settable to 4-20 mA or 0-10 V
- RS485 Modbus RTU digital interface
- Power supply 12...36 VDC (default), 24 VAC as option
Evikon Humidity and temperature transmitter E2218-DM is a member of new PluraSens® family of multifunctional measurement instruments. The transmitter is intended for measurement of relative and absolute humidity, temperature and dew point value in air with high accuracy and stability in non-aggressive gases.
Evikon E2218-DM features two freely configurable analog outputs 4-20 mA / 0-10 V and RS485 Modbus RTU interface for direct Fieldbus networking. The sensors are located at the tip of 200 mm long stem, intended for insertion into ventilation airducts.
RCM general purpose Flo-Gard II flow switches (liquid) reed switches make or break contacts by detecting the position of a magnet permanently attached to the bellow.
Our reed switches can also be ordered for use in hazardous location (Option IS), when fitted with
LED's (Option LED) it provides viewing at a glance when flow rate goes below or above the set point and makes field calibration easy.
Monnit ALTA Wireless Humidity (RH) Sensor allows you to accurately monitor the relative humidity of the air within a room or enclosure. - Measures relative humidity, temp
Monnit ALTA® Wireless Thermocouple Sensors leverage Monnit’s award-winning remote monitoring platform to remotely monitor high-temperature applications, such as commercial ovens, kilns, and chimneys. Users benefit from a wireless data transmission range of 1,200+ ft, bank-grade security, and a temperature range of up to 400°C (752°F).
Monnit’s thermocouple is user-programmed to sleep for a specified interval, awake, capture analog data, and then convert this measurement into a temperature. If the sensor captures temperatures outside of user-specified thresholds, an alert is sent via text, email, or call. Monnit’s hardwired thermocouples feature a needle-style probe at the end of a 6’ lead (a K-Type Quick Connect Thermocouple is also available).
TOKICO FLOWMETER, TOKICO OIL FLOWMETER a high accuracy displacement type flow meter composed of two roots and measures flow directly. Tokico Oil Flowmeter has little deterioration in the instrument accuracy because a couple of roots rotates with non-contact. This flow meter measures with high accuracy and wide flow range.
TOKICO FLOWMETER, TOKICO OIL FLOWMETER is a high accuracy displacement type flow meter composed of two roots and measures flow directly. Tokico Oil Flowmeter has little deterioration in the instrument accuracy because a couple of roots rotates with non-contact. This flow meter measures with high accuracy and wide flow range.
Sekonic Universal 6 channel Recorder SP-100 / SP100 records from different sources simultaneously, including mA, V, PT100, Thermocouple.