Anritsu ACSⅡ series products are temperature calibration systems for surface temperature and internal temperature measuring devices.
Temperatures can be set across a wide range, from room temperature to 500°C. These calibration systems are designed for calibration or to check temperature measuring probes.
Black Body Infrared Calibrator
:
EDL’s Single Black Body (SBB) IR Calibrators were designed for easy and reliable testing of virtually any in line or handheld infrared pyrometer/gun. The Single Black Body (SBB) is used for applications requiring only one temperature range. Lightweight and compact, the SBB is ideal for use in the lab or in the field. Units are available to cover the most tested temperatures: SBB-1 (low-range) accommodates temperatures from -30 °C up to 110 °C, SBB-2 (mid-range) accommodates temperatures from ambient up to 350 °C, and SBB-3 (high-range) accommodates temperatures from ambient up to 650 °C.
Features:
Easily Calibrate Infrared Pyrometers with Multiple Temperature Ranges!EDL's Dual Black Body Infrared (IR) Calibrators allow for faster and easier calibration than ever before! You don't have to be an engineer to operate these units – EDL's calibrators were designed with the user in mind and are simple to set and control. The Dual Zone Black Body Calibrators (DBB) are offered in two versions: the DBB-350 with a low range of: -30 °C up to 135 °C and a high range of: Ambient to 350 °C; and the DBB-650 with a low range of: -30 °C up to 135 °C, and a high range of: Ambient to 650 °C. EDL's Black Bodies are the number one choice for IR Calibrators. These calibrators ensure accurate calibrations of virtually any infrared pyrometer available. With its large target areas of 2”, and high accuracy temperature controller – EDL's IR calibrators offer better accuracy and stability over other IR calibrators on the market. The emissivity of the isothermal target is machined and coated to give a high emissivity of 0.986e, and the target temperature can be controlled in set-point increments of 0.1°. Fast heating and cooling times make these calibrators very efficient. EDL's line of DBB calibrators are easy to use and operate. With no trouble, they can be checked in the field, thanks to the RTD sensor that is easily removed from the Black Body for independent calibration. Our unique design gives you high reliability coupled with high accuracy. Using the calibrator is a breeze. Merely set the desired Black Body temperature from the convenient front panel control buttons, wait a few minutes to ensure stability, aim the gun at the target and shoot. The radiated energy from the Black Body is measured by your IR thermometer. Merely compare its reading to the display on the DBB and record the difference. Data is easily collected and downloaded to the computer through the RS-232 computer interface which allows computer control of the set points. The DBB is drilled to accommodate holes for external 0.125” PRTs (sold separately). A NIST traceable calibration report is included with your initial purchase. All EDL calibrators are made in the USA and tested for stability and uniformity before shipping. Available in 110VAC and 220VAC versions, with European cord sets as required. |